Excavation of a pipeline within a compressor station for the purpose of inspecting the coating integrity resulted in an excavator damaging the pipeline coating. The incident was exacerbated by a lack...
A side-boom was working in tandem with a second side-boom to move a pipeline segment into a trench. The working side of the trench had been elevated by placing the spoil on that side. The segment...
During works at a compressor station, an excavator struck and fractured a 2 inch diameter utility line. Fortunately, no ignition occurred nor were there any injuries. However, the compressor station...
A gas leak occurred at a compressor station when small bore pipework fractured. The incident resulted in a small natural gas release that was successfully resolved without harm, although the licensee...
In late 2010 when a well site was being demobilised, a handrail fell from the sub-base walkway of a draw works skid being moved and struck a worker walking below at ground level. The initial contact...
During a tong jaw change-out operation on a rig floor, a crew member tapped the tong jaw into position using a rubber mallet to insert the pin while two other crew members held the tong to stabilise...
A hydraulic cylinder used to lower and raise a rig’s derrick was found to be faulty and was replaced with a substituted part, rather than that supplied by the original equipment manufacturer (OEM)...
During a mechanical inspection of the crown block on top of a drilling derrick, one of the turnbuckles on the side brake was found to be fractured. A decision was made to repair weld the turnbuckle...
A new member of a drilling crew was asked to clear excess drill cuttings around a “possum belly”. Also known as a distribution box or flowline trap, this part of a drilling rig slows the velocity of...
At the beginning of a work-over operation on an oil well, a mobile lighting tower was erected to provide light during night activities. A few days later, the tower fell onto the lighting plant...
After a cleaning pig run of an oil pipeline, the pig (pipeline inspection gauge) was cleaned, dismantled, checked and reassembled. A cotter pin was required to complete the job. A worker involved in...
An electrical supervisor conducting a walkabout after a pre-start noticed smoke and heard a strange noise coming from a generator. Assuming it could be running out of fuel, he lifted the access cover...
The travelling block of a work-over rig struck the crown of the derrick. After the block hit the crown, the derrick tilted slightly away from the rig floor towards draw works, resulting in failure of...
During repetitive diving operations, using equipment specially designed and built for pipeline construction, a diver’s umbilical was pinched after tangling with an equipment masthead being raised...
Note: The information contained in this significant incident report is based on materials received, knowledge and understanding at the time of writing. An operator at a dewatering spread was required...
An abandonment program was underway on the platform of an offshore drilling rig. The casing strings had been removed from the platform caisson, leaving five 20 inch-diameter conductor pipes. The...
A worker fell about 4 metres after a handrail broke away from its support brackets. He had been standing on the lower access landing of the normally unmanned offshore platform, awaiting transfer from...
Note: The Department of Energy, Mines, Indutsry Regulation and Safety’s investigation was ongoing. The information contained in this significant incident report is based on materials received,...
At a chemical manufacturing plant that produces hydrogen gas and other substances, a potential restriction in the feed line to a hydrogen-fired boiler was identified. Specialist contractors were...
Note: This bulletin is issued to raise awareness of potential suicide risk factors for personnel engaged in the resources sector. It is not intended as an instructional document on suicide prevention...